The Liebherr SUFsg 5001 is a premium upright freezer featuring NoFrost technology, high energy efficiency (A+++), SuperCool function, adjustable temperature zones, glass shelves, interior LED lighting, reversible door, child lock, and alarm system. It is designed for household use with a total capacity of 500 liters. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Temperature Management 7. NoFrost Technology 8. Energy Saving Tips 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Upright freezer cabinet, electronic control panel, NoFrost evaporator, glass shelves, interior LED light, reversible door hinges, door bins, and lockable castors.

FeatureDescription
NoFrost TechnologyPrevents ice buildup automatically; no manual defrosting required
SuperCool FunctionRapidly lowers temperature for new food loads
Energy ClassA+++ for maximum energy efficiency
Adjustable ShelvesGlass shelves that can be repositioned for flexible storage
Interior LightingLED light for clear visibility
Reversible DoorDoor can be hung left or right to suit room layout
Child LockPrevents unintended changes to settings
Temperature AlarmAudible alert if temperature rises above safe level
Lockable CastorsEasy mobility and stable positioning
Total Capacity500 liters net volume

Installation

Unpack and inspect contents. Position on a level, stable floor.

  1. Choose location: Place away from heat sources, with adequate ventilation (min. 5 cm clearance on sides and back).
  2. Adjust feet: Use a spirit level to ensure the appliance is perfectly horizontal.
  3. Set door hinge: Install door on preferred side using included hinge kit.
  4. Connect to power: Plug into a grounded 220-240V AC, 50Hz outlet. Use a dedicated circuit.
  5. Wait before loading: Allow the freezer to stand upright for at least 4 hours after transportation before switching on.

WARNING! The appliance is heavy; use two people for lifting and moving. Ensure the floor can support the weight.

First-Time Setup

After installation, power on the freezer and configure initial settings.

  1. Initial cooling: Turn on the appliance and set to maximum cooling for the first 24 hours.
  2. Set temperature: Use the control panel to set the desired freezer temperature (recommended -18°C).
  3. Activate SuperCool: Press the SuperCool button before loading large amounts of unfrozen food.
  4. Set child lock: Press and hold the lock button for 3 seconds to activate the control panel lock.
  5. Load food: Distribute food evenly across shelves, allowing air circulation.

CAUTION! Do not block air vents inside the cabinet. Overloading can reduce efficiency.

Specifications

Controls and Settings

The electronic control panel is located on the front top of the appliance.

Buttons & Display: POWER ON/OFF, Temperature Adjustment (+/-), SuperCool Button, Alarm Reset, Child Lock Button.

Temperature Setting: Range from -24°C to -16°C. Default recommended setting is -18°C. SuperCool Mode: Activates maximum cooling for approximately 6 hours, then returns to set temperature. Alarm Indicator: Flashes and beeps if internal temperature rises critically (e.g., door left open). Child Lock: Locks the control panel to prevent accidental setting changes.

Temperature Management

For optimal food preservation and energy efficiency.

  1. Recommended temperature: Set to -18°C for long-term storage of frozen food.
  2. Loading warm food: Use the SuperCool function beforehand to compensate for temperature rise.
  3. Avoid frequent door openings: Plan removal of items to minimize cold air loss.
  4. Check seal: Ensure the door gasket is clean and sealing properly.

Tip: Use a separate thermometer to occasionally verify the internal temperature.

NoFrost Technology

The NoFrost system automatically prevents ice formation on the interior walls and shelves.

  1. How it works: A fan circulates cold, dry air throughout the cabinet, preventing moisture from condensing and freezing on surfaces.
  2. Benefits: No need for manual defrosting. Consistent temperature and humidity levels.
  3. Maintenance: The evaporator behind the rear panel defrosts automatically. Ensure air vents are not blocked by food packages.

WARNING! Never use sharp objects to remove ice. If ice forms, it indicates a problem with the door seal or that the NoFrost system requires service.

Energy Saving Tips

Maximize efficiency to reduce electricity consumption.

Care & Cleaning

Unplug the appliance before any cleaning.

  1. Interior: Wipe with a soft cloth dampened with a mild detergent solution. Do not use abrasive cleaners.
  2. Shelves and bins: Remove and wash separately with warm soapy water. Dry thoroughly before replacing.
  3. Door gasket: Clean carefully with water and a soft cloth to maintain seal integrity.
  4. Exterior: Wipe with a damp cloth. For stainless steel models, use appropriate cleaner.
  5. Condenser: Vacuum the rear grille periodically to remove dust.

CAUTION! Never use steam cleaners, scouring pads, or chemical solvents. Do not pour water inside the appliance.

Regulatory Information

This appliance complies with EU Directives 2014/35/EU (LVD), 2014/30/EU (EMC), and 2011/65/EU (RoHS). The refrigerant R600a is flammable but contained within a sealed system. Dispose of the appliance according to local WEEE (Waste Electrical and Electronic Equipment) regulations. For service or support, contact Liebherr Customer Service or visit www.liebherr.com.

Troubleshooting

SymptomPossible CauseCorrective Action
Appliance not coolingPower issue / Incorrect settingCheck if plugged in and power is on. Verify temperature setting is not too warm.
Alarm soundsDoor ajar / Power failureClose door firmly. Check if there was a power outage; food may need inspection.
Excessive frost/ice insideFaulty door seal / NoFrost system errorClean and check door gasket. If problem persists, service is required.
Unusual noisesAppliance not level / Fan obstructionLevel the appliance. Ensure no food packages are touching the rear fan cover.
Control panel unresponsiveChild lock active / Power surgeDeactivate child lock. Unplug for 5 minutes, then reconnect.
High energy consumptionPoor location / Dirty condenserRelocate away from heat sources. Clean the condenser coil.

Reset: Unplug the appliance for 10 minutes to perform a soft reset.

Service: For technical issues not resolved above, contact authorized Liebherr service. Do not attempt to repair the sealed refrigerant system yourself.