The Liebherr GN 50Vd26 is a high-performance commercial freezer designed for professional kitchen use. It features a 50-liter capacity, VdS-certified fire protection, digital temperature control with display, forced air cooling system, stainless steel interior and exterior, automatic defrost, adjustable shelves, and an alarm system for temperature deviations. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Stainless steel cabinet, digital control panel, interior LED lighting, adjustable wire shelves, forced air cooling system, temperature alarm, and VdS fire protection certification.
| Feature | Description |
|---|---|
| Capacity | 50 liters net volume |
| Cooling System | Forced air circulation for even temperature distribution |
| Temperature Range | -18°C to -25°C (adjustable) |
| Control Panel | Digital display with touch controls |
| Interior Light | Energy-efficient LED |
| Shelves | 2 adjustable stainless steel wire shelves |
| Defrost System | Automatic |
| Alarm System | Visual and audible alarm for temperature deviation |
| Certification | VdS fire protection |
| Power Supply | 230V, 50Hz |
Unpack and inspect contents. Ensure location meets requirements.
WARNING! Do not install near heat sources. Ensure electrical outlet is easily accessible.
After installation, allow unit to stabilize before loading.
CAUTION! Do not overload shelves. Keep door openings brief to maintain temperature.
Digital control panel located on front exterior.
Display Symbols: Temperature display, alarm indicator, defrost indicator, power indicator.
Temperature Setting: Press SET button, then use + or - to adjust. Press SET again to confirm. Alarm Settings: Access alarm menu by holding SET for 3 seconds. Set high/low temperature limits. Display Adjustment: Adjust display brightness in settings menu. Reset: Hold + and - simultaneously for 5 seconds to reset to factory defaults.
Requires dedicated 230V, 50Hz grounded outlet.
Tip: Use a surge protector for added safety. Do not use extension cords.
Designed for continuous operation in commercial environments.
WARNING! Do not store flammable materials. Keep ventilation openings clear.
Regular cleaning ensures hygiene and optimal performance.
CAUTION! Do not use abrasive cleaners, solvents, or steam cleaners.
Visual and audible alarms alert to temperature deviations.
High Temperature Alarm: Sounds if temperature rises above set limit for more than 30 minutes. Low Temperature Alarm: Activates if temperature falls below set limit. Door Alarm: Optional accessory alerts if door left open. Alarm Reset: Acknowledge alarm by pressing any button. Alarm limits can be adjusted in settings menu.
CE certified. Complies with EU directives for safety and electromagnetic compatibility. VdS certified for fire protection. Manufactured according to ISO 9001 standards. Contains refrigerant R290 (flammable). For disposal, follow local regulations. Copyright © Liebherr-International AG. For support, visit www.liebherr.com or contact local service center.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power / Display off | Power supply issue | Check plug connection; verify outlet has power; check circuit breaker. |
| Temperature too high | Door left open / Overloaded | Ensure door closes properly; reduce load; check door seal. |
| Unusual noise | Uneven placement / Fan obstruction | Level the appliance; check for items touching fan. |
| Alarm sounds | Temperature deviation | Check temperature setting; verify door seal; allow unit to recover. |
| Excessive frost | Frequent door openings | Minimize door openings; check door seal integrity. |
| Display shows error code | Sensor fault / System error | Note error code; consult service manual; contact technician. |
Reset: Power off for 5 minutes, then restart.
Service: Contact authorized Liebherr service center. Do not attempt repairs yourself.